8Product advantages:
- Easy to clean
- Hygienic handling
- Front loader with door on the narrow side
- The box is finished inside and out in white painted steel, thickness 6/10
Product details:
| Color: |
Silver
|
| Material: |
Stainless steel AISI 304 thickness 6/10
|
| Dimensions: |
90-114 x 96-110 x 90 cm (L x W x H). Door: 85 x 88 cm |
| Voltage: |
230 V / 50 Hz |
| Operating temperature: |
0° C |
| Temperature range: |
-5° C / +5° C |
| Cooling capacity: |
800 W |
| Capacity: |
1 body tray or 1 deceased person |
| Function: |
Cooling and storage of the deceased |
| Areas of application: |
Funeral home, crematorium, mortuary |
| Designation: |
Mortuary refrigeration cell, mortuary refrigeration, mortuary cell, mortuary refrigeration unit, mortuary refrigeration system, deep-freeze cell, refrigeration concept, refrigeration chamber, refrigeration cell block, refrigeration for the deceased, refrigeration cell for mortuary refrigeration |
| Scope of delivery: |
Body cooling cell |
| Please note: |
Shipping surcharge
|
Other product features:
- The installation of cold rooms with compact cooling systems is possible without any particular difficulties. On request, it can also be carried out by specialist technical personnel commissioned directly by the customer. For installation, the installation diagram supplied with the coldroom must be strictly observed. Alternatively, the installation can also be carried out directly by CEABIS technical staff following a prior estimate.
- Electronic control panel with digital display and with thermostat, thermometer, defrost timer and alarm for faults and temperature fluctuations.
- If required, a body tray can be supplied as an additional accessory (-CEA0C030) can be ordered as an additional accessory, which can be used instead of a coffin slide system.
Floor
Floor made of rigid polyurethane foam board reinforced with chipboard,
Thickness 10 mm.
STANDARD SURFACE: Running surface made of galvanized sheet steel,
coated with 200 μ thick rigid PVC film in the color
Grey. The film is non-toxic, self-extinguishing, and complies with the regulations.
Regulations of the health department.
STAINLESS STEEL SURFACE: Running surface made of stainless steel sheet
AISI 304, non-slip, complies with the regulations of
Health department.
insulation
Insulation with self-extinguishing rigid polyurethane foam according to specifications
according to the standard ASTM D 1692, with a density of 40 kg/m3
, CFC-free.
Optimal heat resistance, chemical resistance and
Dimensional stability.
BODY TRAYS AND EQUIPMENT
The body trays are made entirely of stainless steel, seamlessly
Deep-drawn for collecting leaking liquids.
With handles for easy handling of the body trays.
Compartments in the cold storage room with stainless steel rollers for easy movement
Inserting the body trays. The body trays can
with an overhang of at least 50% of the total length
be pulled out for identification of the body or
Autopsy checks. The body tray can be completely
removed from the cold storage room.
TECHNICAL DATA
Refrigeration unit
The refrigeration unit is made of high-quality materials and equipped with
Manufactured using components from the best brands in the industry. It is in the
Available in monoblock version or as a split unit and
Includes condenser, evaporator and control panel with operating unit.
HOUSING: Made of painted sheet steel. The panels can be folded to
Simply remove for maintenance purposes.
COMPRESSOR: Hermetic compressor with cooling by
the aspirated gas. With a fully protected engine and
Electronically regulated thermistors. Operation with
environmentally friendly gas. The gas expands with
capillary tube or thermostatic valve. The rated power is
as specified on the relevant data sheet.
Batteries, electric fan and defrosting
Heat exchanger batteries (evaporator and condenser) made of
Copper pipes. Aluminum frame and ribs with large
Surface for heat exchange. Electric fan for the
Hermetic type evaporator. Defrosting with hot gas and
Heating elements to prevent condensation.
Control panel
Fully automatic and programmed to control all
Cold storage room functions. An electronic control unit enables
the regulation of the instruments depending on the respective
Requirements (thermostat, setting of operating parameters)
with MIN/MAX values, selection of defrost cycle, delay
the switching on of the evaporator fans, pause time after
defrosting for draining the meltwater, temperature alarm,
Temperature sensor control, interior lighting activation,
Protection for the switching frequency of the thermostat).
Standard equipment
- Switching on the light in the cold storage room via a microswitch
at the doors with simultaneous shutdown of the refrigeration unit.
- Electronic control panel with digital display.
- Alarm in case of temperature fluctuations or malfunctions.
- Water drain at the bottom of the cold storage room.
- Condensation protection with heating element on the doors (for cold storage rooms)
(with low temperatures).
Extra accessories
- Doors with viewing window with triple glazing.
- Graphical temperature recording.
- Exhaust system (with or without activated carbon filter).
- Auxiliary cooling unit in "standby".
- Side maintenance door.
- Mounting on casters (only for cold storage rooms with small
Dimensions)
Special versions
- Tropical-grade special cooling units for locations with
particularly unfavorable climate.
- Cooling units with water condensation.
- Cooling units with special power supply (60 Hz).
- Special equipment differing from the standard version
(Cold storage units for ships, etc.).
- Equipped with separate and individually cooled
Corpse compartments.
- Special equipment for infectious and/or radioactive corpses.
- Equipment with customer-specific dimensions.
Assembly and commissioning
The assembly of the cold storage rooms with monoblock cooling units is
Possible without major difficulties and can be arranged in consultation.
also carried out by technical personnel who are directly
commissioned by the client. During installation, the
The enclosed assembly instructions must be strictly followed.
The installation can also be carried out directly by the technical staff of the
The work will be carried out by CEABIS, which can also be done upon request.
Conducts a site visit at the intended installation location.
The installation of cold storage rooms with split units must be carried out by qualified personnel.
The work must be carried out by qualified personnel with experience in the field.
Installation of these types of systems is available.
It is recommended that these installations be carried out directly by personnel of the
to have the company CEABIS carry it out.
Small cold storage rooms (with one or two compartments) can already
They will be delivered fully assembled and packed in wooden crates.
In these cases, the client must specify the dimensions of the
Check the assembled cell and ensure that transport to
the intended installation location is possible.
Add custom text to your tabs